Get a free quote today!

Flexeon LP-700 Reverse Osmosis System Pump-less

Flexeon LP-700 Reverse Osmosis System Pump-less <h3 style="text-align: center;"><strong>Flexeon LP-700 Reverse Osmosis System Pump-less</strong></h3>   <span>The Flexeon LP-700 Reverse Osmosis System is designed to treat 700 gallons per day. This system requirs a minimum of 70psi of incoming water pressure and a maximum TDS of 250ppm.  The pump-less LP-Series provides lower optierational costs and is easy to install and maintain.  Upgraded cover with pressure gauges and a 20" floor stand also available. The Flexeon LP-700 Reverse Osmosis System is designed for pump-less light commercial applications up to 700 gallons per day (at a line pressure of 70 psi and max TDS of 250 ppm). System comes ready for immediate on-line service, minimal set up and little adjustment. The simple, high quality and proven design of Flexeon RO Systems have made these systems become known as turn-key, cost effective and reliable water purification systems.</span>   <p style="text-align: center;"><strong>Product Specifications</strong></p> <table width="832" height="1354"> <tbody> <tr> <td width="344"><strong>DESIGN </strong></td> <td width="371"><strong>                             LP-700</strong></td> </tr> <tr> <td width="344">Configuration</td> <td width="371">  Single Pass</td> </tr> <tr> <td width="344">Feed Water Source (ppm)</td> <td width="371">TDS <250</td> </tr> <tr> <td width="344">Standard Recovery</td> <td width="371">  40%</td> </tr> <tr> <td colspan="2" width="715"><strong>Rejection and Flow Rates</strong></td> </tr> <tr> <td width="344">Nominal Salt Rejection</td> <td width="371">96%</td> </tr> <tr> <td width="344">Nominal Product Water Flow</td> <td width="371">0.5 / 1.9</td> </tr> <tr> <td width="344"> Nominal Waste Water Flow(gpm/lpm)</td> <td width="371"> 0.75 / 2.85</td> </tr> <tr> <td colspan="2" width="715"><strong>Connections</strong></td> </tr> <tr> <td width="344">Feed (in)</td> <td width="371"> 3/8 Tube</td> </tr> <tr> <td width="344">Permeate (in)</td> <td width="371">3/8 Tube</td> </tr> <tr> <td width="344">Concentrate (in)</td> <td width="371">3/8 Tube</td> </tr> <tr> <td colspan="2" width="715"><strong>Membranes</strong></td> </tr> <tr> <td width="344">Membrane Per Vessel</td> <td width="371">1</td> </tr> <tr> <td width="344">Membrane Quantity</td> <td width="371">2</td> </tr> <tr> <td width="344">Membrane Size</td> <td width="371">3012</td> </tr> <tr> <td colspan="2" width="715"><strong>Vessels</strong></td> </tr> <tr> <td width="344">Vessel Array</td> <td width="371">2(parallel)</td> </tr> <tr> <td width="344">Vessel Quantity</td> <td width="371">2</td> </tr> <tr> <td colspan="2" width="715"><strong>System Dimensions</strong></td> </tr> <tr> <td width="344">L X W X H ( in/cm)</td> <td width="371">17 x 7.5 x 29 / 43.2 x 19 x 122.7</td> </tr> <tr> <td width="344">Weight (lb/kg)</td> <td width="371">38 /17.1</td> </tr> <tr> <td colspan="2" width="715"><strong><em>*Product flow and recovery rates are based on feed conditions of 50 TDS at 77◦F at 70 psi. Treatment ability of the RO system is dependent on feedwater quality and feed pressure. Higher TDS and/or lower temperatures and/or pressure will reduce product flow.</em></strong><strong><em> </em></strong>   <p style="text-align: center;"><strong>Operating Limits </strong><strong> </strong></p> <table> <tbody> <tr> <td width="194">Design Temperature</td> <td width="142">77◦F</td> <td width="252">Max. Turbidity NTU</td> <td width="112">1</td> </tr> <tr> <td width="194">Max. Feed Temperature</td> <td width="142">85◦F</td> <td width="252">Max. Free Chlorine ppm</td> <td width="112">0</td> </tr> <tr> <td width="194">Max. Feed Temperature</td> <td width="142">50◦F</td> <td width="252">Max. TDS ppm</td> <td width="112">250</td> </tr> <tr> <td width="194">Max. Ambient Temperature</td> <td width="142">120◦F</td> <td width="252">Max. Hardness GPG</td> <td width="112">1</td> </tr> <tr> <td width="194">Min. Ambient Temperature</td> <td width="142">40◦F</td> <td width="252">Max. pH (Continuous)</td> <td width="112">11</td> </tr> <tr> <td width="194">Max. Pump Inlet Pressure psi</td> <td width="142">85</td> <td width="252">Min. pH (continuous)</td> <td width="112">3</td> </tr> <tr> <td width="194">Min. Pump Inlet Pressure psi</td> <td width="142">45</td> <td width="252">Max.pH (Cleaning 30 min.)</td> <td width="112">12</td> </tr> <tr> <td width="194">Max. SDI Rating</td> <td width="142"><1</td> <td width="252">Min. pH (Cleaning 30 Min.)</td> <td width="112">2</td> </tr> </tbody> </table> </td> </tr> <tr> <td colspan="2" width="715"><strong> Test Parameters: Static pressure tested.</strong> * Appropriate Pre-filtration must be installed in order to prevent premature membrane fouling. *Scale prevention measures must be taken to prolong membrane life.</td> </tr> <tr> <td colspan="2" width="715"><strong> </strong></td> </tr> </tbody> </table> <h5></h5> <h5><strong><em>                             </em></strong></h5> <h5><strong><em> </em></strong></h5>  
$995.00

Home / Shop

Flexeon LP-700 Reverse Osmosis System Pump-less

$1595.00$995.00
Flexeon LP-700 Reverse Osmosis System Pump-less
Flexeon LP-700 Reverse Osmosis System Pump-less

Home / Shop

Flexeon LP-700 Reverse Osmosis System Pump-less

$1595.00$995.00
Model Number: Flexeon LP-700 Reverse Osmosis System Pump-less
Maximum quantity exceeded
Minimum purchase amount of 0 is required
Maximum purchase amount of 0 is allowed
995.000
Manufacturer:
Facebook
Twitter
Email
Pinterest
Google+
LinkedIn
Digg
  • Description

Flexeon LP-700 Reverse Osmosis System Pump-less

  The Flexeon LP-700 Reverse Osmosis System is designed to treat 700 gallons per day. This system requirs a minimum of 70psi of incoming water pressure and a maximum TDS of 250ppm.  The pump-less LP-Series provides lower optierational costs and is easy to install and maintain.  Upgraded cover with pressure gauges and a 20" floor stand also available. The Flexeon LP-700 Reverse Osmosis System is designed for pump-less light commercial applications up to 700 gallons per day (at a line pressure of 70 psi and max TDS of 250 ppm). System comes ready for immediate on-line service, minimal set up and little adjustment. The simple, high quality and proven design of Flexeon RO Systems have made these systems become known as turn-key, cost effective and reliable water purification systems.  

Product Specifications

DESIGN                              LP-700
Configuration   Single Pass
Feed Water Source (ppm) TDS <250
Standard Recovery   40%
Rejection and Flow Rates
Nominal Salt Rejection 96%
Nominal Product Water Flow 0.5 / 1.9
 Nominal Waste Water Flow(gpm/lpm)  0.75 / 2.85
Connections
Feed (in)  3/8 Tube
Permeate (in) 3/8 Tube
Concentrate (in) 3/8 Tube
Membranes
Membrane Per Vessel 1
Membrane Quantity 2
Membrane Size 3012
Vessels
Vessel Array 2(parallel)
Vessel Quantity 2
System Dimensions
L X W X H ( in/cm) 17 x 7.5 x 29 / 43.2 x 19 x 122.7
Weight (lb/kg) 38 /17.1
*Product flow and recovery rates are based on feed conditions of 50 TDS at 77◦F at 70 psi. Treatment ability of the RO system is dependent on feedwater quality and feed pressure. Higher TDS and/or lower temperatures and/or pressure will reduce product flow.   

Operating Limits  

Design Temperature 77◦F Max. Turbidity NTU 1
Max. Feed Temperature 85◦F Max. Free Chlorine ppm 0
Max. Feed Temperature 50◦F Max. TDS ppm 250
Max. Ambient Temperature 120◦F Max. Hardness GPG 1
Min. Ambient Temperature 40◦F Max. pH (Continuous) 11
Max. Pump Inlet Pressure psi 85 Min. pH (continuous) 3
Min. Pump Inlet Pressure psi 45 Max.pH (Cleaning 30 min.) 12
Max. SDI Rating <1 Min. pH (Cleaning 30 Min.) 2
 Test Parameters: Static pressure tested. * Appropriate Pre-filtration must be installed in order to prevent premature membrane fouling. *Scale prevention measures must be taken to prolong membrane life.