Get a free quote today!

FLEXEON LC-750 Reverse Osmosis System

FLEXEON LC-750 Reverse Osmosis System <h3 style="text-align: center;"><strong>FLEXEON LC-750 Reverse Osmosis System</strong></h3> <h4 style="text-align: center;"></h4> <strong>LC-Series Reverse Osmosis Systems</strong> <strong>FLEXEON LC-Series Reverse  Osmosis Systems </strong>are manufactured for light commercial applications and feature a compact space-saving design. The versatile design allows for either wall-mounted or free-standing operation. The LC-Series Systems comes pre-assembled, and ready for immediate on-line service with minimal set up and simple utility connections. <strong>FLEXEON LC-Series Reverse Osmosis Systems </strong> have been engineered for capacities ranging from 750 to 1,500 gallons per day, and feature a Fluid-O-Tech Low Lead Brass Rotary Vane pump designed for enhanced performance.   <strong>Standard Features    </strong> <ul> <li><strong></strong>White Powder Coated Steel Bracket</li> <li>10 Micron Carbon Block Pre-Filter ( on LC-750)</li> <li>AXEON by Pentek Housings</li> <li>Fluid-O-Tech Low Lead Brass Rotary Vane High Pressure Pump</li> <li>ODP High Efficiency Carbonator Motor</li> <li>AXEON HF5-Series Ultra Low Energy Membranes</li> <li>Permeate Flow Meter</li> <li>Concentrate Flow Meter</li> <li>Concentrate Recycle Flow Meter</li> <li>Feed Solenoid Valve</li> <li>316 Stainless Steel Concentrate and Recycle Valves</li> <li>0- 300 psi Pump Pressure Gauge</li> <li>0- 100 psi Post-Filter Pressure Gauge</li> <li>0- 100 psi Permeate Pressure Gauge</li> <li>John Guest Push/Pull Fittings with Locking Safety Clips</li> <li>Low Pressure Switch for Pump Protection</li> <li>Permeate High Pressure Switch</li> <li>HM Digital DM-2 TDS Meter</li> <li>20’’</li> </ul> <strong>Options and Upgrades</strong> <ul> <li>Storage Tanks</li> <li>Fluid-O-Tech Stainless Steel Rotary Vane Pump</li> <li>Blending Valve</li> </ul>   <p style="text-align: center;"><strong>Product Specifications</strong></p> <p style="text-align: center;"></p> <table> <tbody> <tr> <td width="344"><strong>DESIGN </strong></td> <td width="371"><strong>                              LC-750</strong></td> </tr> <tr> <td width="344">Configuration</td> <td width="371">                           Single Pass</td> </tr> <tr> <td width="344">Feed Water Source (ppm)</td> <td width="371">                            TDS up to 1,000</td> </tr> <tr> <td width="344">Standard Recovery <strong> </strong></td> <td width="371">                             Up to 75%</td> </tr> <tr> <td colspan="2" width="715"><strong>Rejection and Flow Rates</strong></td> </tr> <tr> <td width="344">Nominal Salt Rejection</td> <td width="371">                               98.5%</td> </tr> <tr> <td width="344">Permeate Flow Rate</td> <td width="371">                             0.52 gpm</td> </tr> <tr> <td width="344">Concentrate Flow Rate ( min.)</td> <td width="371">                             1.7 gpm ( 6.4) lpm)</td> </tr> <tr> <td width="344">Concentrate Recycle Flow Rate</td> <td width="371">                              1.4 gpm (5.2 lpm)</td> </tr> <tr> <td colspan="2" width="715"><strong>Connections</strong></td> </tr> <tr> <td width="344">Feed (in)</td> <td width="371">                               3/8 QC</td> </tr> <tr> <td width="344">Permeate (in)</td> <td width="371">                               3/8 QC</td> </tr> <tr> <td width="344">Concentrate (in)</td> <td width="371">                               3/8 QC</td> </tr> <tr> <td colspan="2" width="715"><strong>Membranes</strong></td> </tr> <tr> <td width="344">Membrane Per Vessel</td> <td width="371">                                 1</td> </tr> <tr> <td width="344">Membrane Quantity</td> <td width="371">                                 1</td> </tr> <tr> <td width="344">Membrane Size</td> <td width="371">                                 3018</td> </tr> <tr> <td colspan="2" width="715"><strong>Vessels</strong></td> </tr> <tr> <td width="344">Vessel Array</td> <td width="371">                                 1</td> </tr> <tr> <td width="344">Vessel Quantity <strong> </strong></td> <td width="371">                                 1</td> </tr> <tr> <td colspan="2" width="715"><strong>Pumps</strong></td> </tr> <tr> <td width="344">Pump Type</td> <td width="371">                        Rotary Vane 401 Low Lead Brass</td> </tr> <tr> <td width="344">Motor ( HP)</td> <td width="371">                                 1/3 HP</td> </tr> <tr> <td width="344">RPM@ 60 HZ</td> <td width="371">                                  1725</td> </tr> <tr> <td colspan="2" width="715"><strong>Electrical </strong></td> </tr> <tr> <td width="344">Standard Voltage</td> <td width="371">                                110 V, 1PH ,60 HZ</td> </tr> <tr> <td colspan="2" width="715"><strong>System Dimensions</strong></td> </tr> <tr> <td width="344">*Approx. Dimensions L X W X H ( in/cm)</td> <td width="371">                17 x 7.5 x 29 ( 43.18 x 19.05 x 73.66)</td> </tr> <tr> <td width="344">*Approx. Weight (lb/kg)</td> <td width="371">                                    50( 22.68)</td> </tr> <tr> <td colspan="2" width="715"> <h5><strong><em>*Product flow and recovery rates are based on feed conditions of 1000 ppm TDS at 77◦.Treatment ability of the RO System is dependent on feed water quality. Higher TDS and/or lower temperatures will reduce product flow. Performance projections should be run for each installation.</em></strong></h5> <strong> </strong> <strong>                                                                                      Operating Limits </strong><strong> </strong> <table> <tbody> <tr> <td width="194">Design Temperature</td> <td width="142">77◦F</td> <td width="252">Max. Turbidity NTU</td> <td width="112">1</td> </tr> <tr> <td width="194">Max. Feed Temperature</td> <td width="142">85◦F</td> <td width="252">Max. Free Chlorine ppm</td> <td width="112">0</td> </tr> <tr> <td width="194">Min. Feed Temperature</td> <td width="142">40◦F</td> <td width="252">Max. TDS ppm</td> <td width="112">Up to 1,000</td> </tr> <tr> <td width="194">Max. Ambient Temperature</td> <td width="142">120◦F</td> <td width="252">Max. Hardness GPG</td> <td width="112">1</td> </tr> <tr> <td width="194">Min. Ambient Temperature</td> <td width="142">40◦F</td> <td width="252">Max. pH (Continuous)</td> <td width="112">11</td> </tr> <tr> <td width="194">Max. Feed Pressure (psi)</td> <td width="142">85</td> <td width="252">Min. pH (continuous)</td> <td width="112">5</td> </tr> <tr> <td width="194">Min. Feed Pressure (psi)</td> <td width="142">45</td> <td width="252">Max.pH (Cleaning 30 min.)</td> <td width="112">12</td> </tr> <tr> <td width="194">Max. Operating Pressure (psi)</td> <td width="142">90</td> <td width="252">Min. pH (Cleaning 30 Min.)</td> <td width="112">2</td> </tr> <tr> <td width="194">Max. SDI Rating (SDI)</td> <td width="142"><3</td> <td width="252"></td> <td width="112"></td> </tr> </tbody> </table> </td> </tr> <tr> <td colspan="2" width="715"><strong> </strong></td> </tr> <tr> <td colspan="2" width="715"><strong> </strong></td> </tr> </tbody> </table> <h5><strong><em>Test Parameters: Static pressure tested.</em></strong></h5> <h5><strong><em>                             * Appropriate Pre-filtration must be installed in order to prevent premature membrane fouling.</em></strong></h5> <h5><strong><em>                             *Scale prevention measures must be taken to prolong membrane life. </em></strong></h5>  
$2595.00

Home / Shop

FLEXEON LC-750 Reverse Osmosis System

$3995.00$2,595.00
FLEXEON LC-750 Reverse Osmosis System
FLEXEON LC-750 Reverse Osmosis System

Home / Shop

FLEXEON LC-750 Reverse Osmosis System

$3995.00$2,595.00
Model Number: FLEXEON LC-750 Reverse Osmosis System
Maximum quantity exceeded
Minimum purchase amount of 0 is required
Maximum purchase amount of 0 is allowed
2595.000
Manufacturer:
Facebook
Twitter
Email
Pinterest
Google+
LinkedIn
Digg
  • Description

FLEXEON LC-750 Reverse Osmosis System

LC-Series Reverse Osmosis Systems FLEXEON LC-Series Reverse  Osmosis Systems are manufactured for light commercial applications and feature a compact space-saving design. The versatile design allows for either wall-mounted or free-standing operation. The LC-Series Systems comes pre-assembled, and ready for immediate on-line service with minimal set up and simple utility connections. FLEXEON LC-Series Reverse Osmosis Systems  have been engineered for capacities ranging from 750 to 1,500 gallons per day, and feature a Fluid-O-Tech Low Lead Brass Rotary Vane pump designed for enhanced performance.   Standard Features    
  • White Powder Coated Steel Bracket
  • 10 Micron Carbon Block Pre-Filter ( on LC-750)
  • AXEON by Pentek Housings
  • Fluid-O-Tech Low Lead Brass Rotary Vane High Pressure Pump
  • ODP High Efficiency Carbonator Motor
  • AXEON HF5-Series Ultra Low Energy Membranes
  • Permeate Flow Meter
  • Concentrate Flow Meter
  • Concentrate Recycle Flow Meter
  • Feed Solenoid Valve
  • 316 Stainless Steel Concentrate and Recycle Valves
  • 0- 300 psi Pump Pressure Gauge
  • 0- 100 psi Post-Filter Pressure Gauge
  • 0- 100 psi Permeate Pressure Gauge
  • John Guest Push/Pull Fittings with Locking Safety Clips
  • Low Pressure Switch for Pump Protection
  • Permeate High Pressure Switch
  • HM Digital DM-2 TDS Meter
  • 20’’
Options and Upgrades
  • Storage Tanks
  • Fluid-O-Tech Stainless Steel Rotary Vane Pump
  • Blending Valve
 

Product Specifications

DESIGN                               LC-750
Configuration                            Single Pass
Feed Water Source (ppm)                             TDS up to 1,000
Standard Recovery                                Up to 75%
Rejection and Flow Rates
Nominal Salt Rejection                                98.5%
Permeate Flow Rate                              0.52 gpm
Concentrate Flow Rate ( min.)                              1.7 gpm ( 6.4) lpm)
Concentrate Recycle Flow Rate                               1.4 gpm (5.2 lpm)
Connections
Feed (in)                                3/8 QC
Permeate (in)                                3/8 QC
Concentrate (in)                                3/8 QC
Membranes
Membrane Per Vessel                                  1
Membrane Quantity                                  1
Membrane Size                                  3018
Vessels
Vessel Array                                  1
Vessel Quantity                                    1
Pumps
Pump Type                         Rotary Vane 401 Low Lead Brass
Motor ( HP)                                  1/3 HP
RPM@ 60 HZ                                   1725
Electrical
Standard Voltage                                 110 V, 1PH ,60 HZ
System Dimensions
*Approx. Dimensions L X W X H ( in/cm)                 17 x 7.5 x 29 ( 43.18 x 19.05 x 73.66)
*Approx. Weight (lb/kg)                                     50( 22.68)
*Product flow and recovery rates are based on feed conditions of 1000 ppm TDS at 77◦.Treatment ability of the RO System is dependent on feed water quality. Higher TDS and/or lower temperatures will reduce product flow. Performance projections should be run for each installation.
                                                                                        Operating Limits  
Design Temperature 77◦F Max. Turbidity NTU 1
Max. Feed Temperature 85◦F Max. Free Chlorine ppm 0
Min. Feed Temperature 40◦F Max. TDS ppm Up to 1,000
Max. Ambient Temperature 120◦F Max. Hardness GPG 1
Min. Ambient Temperature 40◦F Max. pH (Continuous) 11
Max. Feed Pressure (psi) 85 Min. pH (continuous) 5
Min. Feed Pressure (psi) 45 Max.pH (Cleaning 30 min.) 12
Max. Operating Pressure (psi) 90 Min. pH (Cleaning 30 Min.) 2
Max. SDI Rating (SDI) <3
 
 
Test Parameters: Static pressure tested.
                             * Appropriate Pre-filtration must be installed in order to prevent premature membrane fouling.